UL10269 SHIELDED CABLE
File No.: E214500
-- 30AWG-2000 kcmil Tinned ,annealed,stranded or solid copper conductor.
-- PVC insulation.
-- Rated temperature:80 90 OR 105℃.Rated voltage:1000 Vac or 1250 Vdc.
-- Uniform thickness of wire to ensure easy stripping and cutting.
-- Passes UL VW-1&CUL FT1 vertical flamt test.
-- Top coated conductor is avaiable.
-- Internal Wiring of Appliances; or Internal Wiring of Appliances where exposed to oil at a temperature not electronic use only exceeding 60 deg. C or 80 deg. C (whichever is applicable).
-- Tags may also indicate the following: 3,500 V peak - for electronic use only.
UL Style& CUL Type | Conductor | Insulation Thickness |
Overall Dimeter |
Stand Put-up | Conductor Resistance at 20℃ |
||
AWG | No/mm | ||||||
mm | mm | Ft/coil | M/Coil | Ω/KM | |||
UL10269 | 30 | 7/0.10 | 0.76 | 1.90 | 2000 | 610 | 381.00 |
28 | 7/0.127 | 0.76 | 2.00 | 2000 | 610 | 239.00 | |
26 | 7/0.16 | 0.76 | 2.10 | 2000 | 610 | 150.00 | |
24 | 11/0.16 | 0.76 | 2.20 | 2000 | 610 | 94.20 | |
22 | 17/0.16 | 0.76 | 2.40 | 2000 | 610 | 59.40 | |
20 | 21/0.178 | 0.76 | 2.50 | 2000 | 610 | 36.70 | |
18 | 34/0.178 | 0.76 | 2.80 | 2000 | 610 | 23.20 | |
16 | 26/0.254 | 0.76 | 3.10 | 1000 | 305 | 14.60 | |
14 | 41/0.254 | 0.76 | 3.50 | 1000 | 305 | 8.96 | |
12 | 65/0.254 | 0.76 | 4.00 | 1000 | 305 | 5.64 | |
10 | 105/0.254 | 0.76 | 4.60 | 1000 | 305 | 3.54 | |
8 | 165/0.254 | 1.15 | 6.50 | 500 | 152.5 | 2.23 | |
6 | 266/0.254 | 1.53 | 8.50 | 500 | 152.5 | 1.40 | |
4 | 420/0.254 | 1.53 | 10.00 | 500 | 152.5 | 0.88 | |
2 | 665/0.254 | 1.53 | 11.80 | 500 | 152.5 | 0.55 | |
1 | 836/0.254 | 2.04 | 14.00 | 250 | 76.25 | 0.44 | |
1/0 | 1064/0.254 | 2.04 | 15.00 | 250 | 76.25 | 0.35 | |
2/0 | 1330/0.254 | 2.04 | 16.50 | 250 | 76.25 | 0.28 | |
3/0 | 1672/0.254 | 2.04 | 18.00 | 250 | 76.25 | 0.22 | |
4/0 | 2109/0.254 | 2.04 | 20.20 | 250 | 76.25 | 0.17 |