FLRY-A LOW-VOLTAGE CABLES IN MOTOR VEHICLES
FL: Low-tension cables
R: Reduced thickness of insulation
Y: Polyvinyl chloride insulated
A: Symmetrical conductor setup
Wire harness of low-tension electric circuits for automobiles.
Conductor: Annealed or tinned stranded copper
Insulation: Lead-free polyvinyl chloride (100°C)
DIN 72551
VW 60306 (Reference)
Conductor |
Min insulation thickness |
Overall diameter |
Conductor resistance |
Weight |
Package |
||||
Size |
Construction |
Sec area |
Diameter |
Nominal |
Maximum |
||||
mm2 |
No./mm |
mm2 |
mm |
mm |
mm |
mm |
mΩ/m |
kg/km |
m |
0.22 |
7/0.21 |
0.242 |
0.64 |
0.2 |
1.1 |
1.2 |
84.8 |
3.1 |
500 |
0.35 |
7/0.26 |
0.372 |
0.79 |
0.2 |
1.2 |
1.3 |
52 |
4.5 |
500 |
0.5 |
19/0.19 |
0.539 |
0.96 |
0.22 |
1.5 |
1.6 |
37.1 |
6.6 |
500 |
0.75 |
19/0.23 |
0.789 |
1.16 |
0.24 |
1.7 |
1.9 |
24.7 |
9 |
500 |
1.0 |
19/0.26 |
1.009 |
1.31 |
0.24 |
1.9 |
2.1 |
18.5 |
11 |
500 |
1.5 |
19/0.32 |
1.528 |
1.61 |
0.24 |
2.2 |
2.4 |
12.7 |
16 |
500 |
2.5 |
19/0.41 |
2.508 |
2.06 |
0.28 |
2.8 |
3 |
7.6 |
26 |
200 |